Home Owner Install Builder Dealer Supplier Designer Engineer




Home About Us Products Photo Gallery Technical Installer Dealer Request Contact Us
Case Studies
Technical Guide
Request Info
Fire Resistance | Control Joints | Control Joint Slots | Sound Reduction | Compressive Strength | Weight Classifications | Integrally Colored CMU

Control Joints

Control joints are employed in crack control to reduce restraint by accommodating movement of the masonry wall, or movement of structural elements adjacent to the wall. Their spacing along the wall will depend on;
  • The expected movements of the wall or other elements.
  • The resistance of the wall to horizontal tensile stress.
  • The extent and location in the wall of windows, doors, recesses, chases, and other causes of stress concentration.
Control joints should be used in conjunction with bond beams and joint reinforcement for crack control purposes.


* More detailed information about Control Joints can be found on our website www.superliteblock.com. Select the e-TEK manual link from our home page, next select the Table of Contents, and finally select Section Ten titled Movement Control.
Privacy Policy | Legal Notice | Support Site by Clearimaging.com
Crego Block - 6140 2nd Street NW, Albuquerque, NM 87107
Phone: 505-345-4451